MFS
DPS-100/100SW
DPS-100 Module
BY-PASS VALVE
Description
Semiconductor and display manufacturing process absolutely need Dry Pump for low vacuum. We need Power and N2 gas purge. Introducing the innovative DPS-100 product that can reduce power consumption by 50% without additional Utility Setup in the Fab Line. (Winner of Korea's Excellent Patent Award in 2018)
Feature
• Simple and easy to install.
• Dry & Rotary Pump All Major products
are applicable.
• Pump Damage Zero, which can occur
when a product fails.
• Built-in pre-safety against heat and failure
in the product.
• No additional utility construction is required
due to the use of pump power.
• Smart size is not limited by the installation space.
• Products that have acquired domestic patents
and CE certification
Specification
| Items | DPS-100 | DPS-100SW |
| Exhaust Speed | 100slm | |
| Vacuum Level | 50torr | |
| Power | 1ph 220V 50/60Hz | |
Power Consumption | 200W (+/-10%) | |
Rated Current | 1.0A (+/-10%) | |
Footprint (mm) | W/250 L/400 H/220 | W/160 L/360 H/285 |
Weight (Kg) | 14 | |
(Frequency Control Inverter Control)
FCIC

Inverter Control

Compressor Frequency Control
Description
Major manufacturers of semiconductor and display use cryo pump systems. Process Chamber is produced in the highest quality in a high vacuum state using it. This FCIC product uses real time monitoring and control of the Cryo Pump temperature by compressor This product reduce Cryo pump power by up to 40% a monte(2.0KwH).
Feature
• ULVAC Cryo Pump system products
are applicable.
• Both semiconductor and Display Water Pump
systems are applicable.
• Compressor Damage Zero, which can occur
when a product fails.
• Application of circuit breaker safety distribution
box without affecting compressor
• Frequency conversion values at Cryo Pump
primary and secondary temperatures may be
set respectively
• Frequency conversion latency can be set
for Inverter protection
• There is no need for a separate utility other
than 220 VAC for commercial power.
• Domestic patent and CE certified products.
(Patent number: 10-2017-0052565)
Specification
| Input voltage 200V class (7.5kW) | MFI-55MC | MFI-75MC | |
| Application motor | |||
| [HP] | 7.5 | 10 | |
| [kW] | 5.5 | 7.5 | |
| Output rating | |||
Rated capacity[kVA] | 9.1 | 12.2 | |
Rated current[A] | CT | 24 | 32 |
VT | 32 | 46 | |
Output frequency | 0~400 [Hz] (Sensorless-1: 0~300Hz, Sensolress-2, Vector:0~120Hz) | ||
| Output voltage[V] | 3 phase 200~230V | ||
| Input rating | |||
| Working Voltage[V] | 3 phase 200~230VAC (-15%~+10%) | ||
| Input frequency | 50~60 [Hz] (±5%) | ||
| Rated current[A] | CT | 22.1 | 28.6 |
VT | 28.6 | 41.2 | |
| Size(WxHxD)(Unit: mm) | 450x700 x355 | 450x700 x355 |
* Built in current connection or cut off circuit that does not affect the compressor
MFS
DPS-100/100SW
DPS-100 Module
BY-PASS VALVE
Description
Semiconductor and display manufacturing process absolutely need Dry Pump for low vacuum.
We need Power and N2 gas purge.
Introducing the innovative DPS-100 product that can reduce power consumption by 50% without additional Utility Setup in the Fab Line.
(Winner of Korea's Excellent Patent Award in 2018)
Feature
• Simple and easy to install.
• Dry & Rotary Pump All Major products are applicable.
• Pump Damage Zero, which can occur when a product fails.
• Built-in pre-safety against heat and failure in the product.
• No additional utility construction is required due to the use of pump power.
• Smart size is not limited by the installation space.
• Products that have acquired domestic patents and CE certification
Specification
Items | Exhaust Speed | Vacuum Level | Power | Power Consumption | Rated Current | Footprint (mm) | Weight (Kg) |
DPS- 100 | 100slm | 50torr | 1ph 220V 50/60Hz | 200W (+/-10%) | 1.0A (+/-10%) | W/250 L/400 H/220 | 14 |
DPS- 100SW | W/160 L/360 H/285 |
(Frequency Control Inverter Control)
FCIC

Inverter Control

Compressor Frequency Control
Description
Major manufacturers of semiconductor and display use cryo pump systems.
Process Chamber is produced in the highest quality in a high vacuum state using it.
This FCIC product uses real time monitoring and control of the Cryo Pump temperature by compressor
This product reduce Cryo pump power by up to 40% a monte(2.0KwH).
Feature
• ULVAC Cryo Pump system products are applicable.
• Both semiconductor and Display Water Pump systems are applicable.
• Compressor Damage Zero, which can occur when a product fails.
• Application of circuit breaker safety distribution box without affecting compressor
• Frequency conversion values at Cryo Pump primary and secondary
temperatures may be set respectively
• Frequency conversion latency can be set for Inverter protection
• There is no need for a separate utility other than 220 VAC for commercial power.
• Domestic patent and CE certified products. (Patent number: 10-2017-0052565)
Specification
| Input voltage 200V class (7.5kW) | MFI-55MC | MFI-75MC | ||
| Application motor | [HP] | 7.5 | 10 | |
| [kW] | 5.5 | 7.5 | ||
| Output rating | Rated capacity[kVA] | 9.1 | 12.2 | |
| Rated current[A] | CT | 24 | 32 | |
| VT | 32 | 46 | ||
| Output frequency | 0~400 [Hz](Sensorless-1:0~300Hz, Sensolress-2, Vector:0~120Hz) | |||
| Output voltage[V] | 3 phase 200~230V | |||
| Input rating | Working Voltage[V] | 3 phase 200~230VAC (-15%~+10%) | ||
| Input frequency | 50~60 [Hz] (±5%) | |||
| Rated current[A] | CT | 22.1 | 28.6 | |
| VT | 28.6 | 41.2 | ||
| Size(WxHxD)(Unit: mm) | 450x700x355 | 450x700x355 | ||
* Built in current connection or cut off circuit that does not affect the compressor