MFS

DPS-100/100SW

DPS-100 Module

BY-PASS VALVE


Description

Semiconductor and display manufacturing process absolutely need Dry Pump for low vacuum. We need Power and N2 gas purge. Introducing the innovative DPS-100 product that can reduce power consumption by 50% without additional Utility Setup in the Fab Line. (Winner of Korea's Excellent Patent Award in 2018)

Feature

• Simple and easy to install. 

• Dry & Rotary Pump All Major products

  are applicable.

 

• Pump Damage Zero, which can occur

  when a product fails.

 

• Built-in pre-safety against heat and failure

  in the product.

 

• No additional utility construction is required

  due to the use of pump power.

 

• Smart size is not limited by the installation space. 

• Products that have acquired domestic patents

  and CE certification

Specification

Items

DPS-100

DPS-100SW

Exhaust Speed
100slm
Vacuum Level
50torr
Power

1ph 220V 50/60Hz

Power

Consumption

200W (+/-10%)

Rated Current

1.0A (+/-10%)

Footprint (mm)

W/250

L/400

H/220

W/160

L/360

H/285

Weight (Kg)

14

(Frequency Control Inverter Control)

FCIC

Inverter Control

Compressor Frequency Control


Description

Major manufacturers of semiconductor and display use cryo pump systems. Process Chamber is produced in the highest quality in a high vacuum state using it. This FCIC product uses real time monitoring and control of the Cryo Pump temperature by compressor This product reduce Cryo pump power by up to 40% a monte(2.0KwH).

Feature

• ULVAC Cryo Pump system products

  are applicable.

 

• Both semiconductor and Display Water Pump

  systems are applicable.

 

• Compressor Damage Zero, which can occur

  when a product fails.

 

• Application of circuit breaker safety distribution

  box without affecting compressor

 

• Frequency conversion values at Cryo Pump

  primary and secondary temperatures may be

  set respectively 

• Frequency conversion latency can be set

  for Inverter protection

 

• There is no need for a separate utility other

  than 220 VAC for commercial power.

 

• Domestic patent and CE certified products.

  (Patent number: 10-2017-0052565)

Specification

Input voltage 200V
class (7.5kW)

MFI-55MC

MFI-75MC

Application motor
[HP]
7.5
10
[kW]
5.5
7.5
Output rating

Rated capacity[kVA]

9.1

12.2

Rated

current[A]

CT

24

32
VT
32
46

Output frequency

0~400 [Hz] (Sensorless-1:
0~300Hz, Sensolress-2,
Vector:0~120Hz)
Output voltage[V]
3 phase 200~230V
Input rating
Working Voltage[V]
3 phase 200~230VAC
(-15%~+10%)
Input frequency
50~60 [Hz] (±5%)
Rated current[A]
CT
22.1
28.6
VT
28.6
41.2
Size(WxHxD)(Unit: mm)
450x700
x355
450x700
x355

* Built in current connection or cut off circuit that does not affect the compressor

MFS

DPS-100/100SW

DPS-100 Module

BY-PASS VALVE


Description

Semiconductor and display manufacturing process absolutely need Dry Pump for low vacuum.

We need Power and N2 gas purge.

Introducing the innovative DPS-100 product that can reduce power consumption by 50% without additional Utility Setup in the Fab Line.

(Winner of Korea's Excellent Patent Award in 2018)

Feature

• Simple and easy to install. 

• Dry & Rotary Pump All Major products are applicable. 

• Pump Damage Zero, which can occur when a product fails. 

• Built-in pre-safety against heat and failure in the product. 

• No additional utility construction is required due to the use of pump power. 

• Smart size is not limited by the installation space. 

• Products that have acquired domestic patents and CE certification

Specification

Items
Exhaust Speed
Vacuum Level
Power

Power

Consumption

Rated

Current

Footprint

(mm)

Weight

(Kg)

DPS-

100

100slm
50torr

1ph

220V

50/60Hz

200W

(+/-10%)

1.0A

(+/-10%)

W/250 L/400

H/220

14

DPS-

100SW

W/160 L/360

H/285

(Frequency Control Inverter Control)

FCIC

Inverter Control

Compressor Frequency Control


Description

Major manufacturers of semiconductor and display use cryo pump systems.

Process Chamber is produced in the highest quality in a high vacuum state using it.

This FCIC product uses real time monitoring and control of the Cryo Pump temperature by compressor

This product reduce Cryo pump power by up to 40% a monte(2.0KwH).

Feature

• ULVAC Cryo Pump system products are applicable. 

• Both semiconductor and Display Water Pump systems are applicable. 

• Compressor Damage Zero, which can occur when a product fails. 

• Application of circuit breaker safety distribution box without affecting compressor 

• Frequency conversion values at Cryo Pump primary and secondary

  temperatures may be set respectively 

• Frequency conversion latency can be set for Inverter protection 

• There is no need for a separate utility other than 220 VAC for commercial power.

• Domestic patent and CE certified products. (Patent number: 10-2017-0052565)

Specification

Input voltage 200V class (7.5kW)MFI-55MCMFI-75MC
Application motor[HP]7.510
[kW]5.57.5
Output ratingRated capacity[kVA]9.112.2
Rated current[A]
CT2432
VT3246
Output frequency0~400 [Hz](Sensorless-1:0~300Hz, Sensolress-2, Vector:0~120Hz)
Output voltage[V]3 phase 200~230V
Input ratingWorking Voltage[V]3 phase 200~230VAC (-15%~+10%)
Input frequency50~60 [Hz] (±5%)
Rated current[A]CT22.128.6
VT28.641.2

Size(WxHxD)(Unit: mm)450x700x355450x700x355

* Built in current connection or cut off circuit that does not affect the compressor

CEO. Jang Yil-Sun

Company. HAMA Solution Co., Ltd.

Office. 202 E-dong, 23 Dongtangiheung-ro 257 beonga-gil Hwaseong-Si, Gyeonggi-do, Korea(18487)

copyright. HAMA Solution. ALL RIGHT RESERVED

CEO. Jang Yil-Sun

Company. HAMA Solution Co., Ltd.

Office. 202 E-dong, 23 Dongtangiheung-ro 257 beonga-gil Hwaseong-Si, Gyeonggi-do, Korea(18487)

copyright. HAMA Solution. ALL RIGHT RESERVED